  • two thresholds set at manufacturing stage;
  • semiconductor sensor for combustible gases or electrochemical sensor for toxic gases or oxygen;
  • easily exchangeable sensor unit for straightforward maintenance;
  • easy change of detected gas and easy calibration (all available DG/F sensor units ready to operate in each DG/F detector);
  • intelligent sensors with build-in TWA and STEL measurement, alarm history, recommended calibration time mark signal;
  • built-in temperature compensation;
  • low cost operation;
  • long time operation (typically 10 years for semiconductor sensors);
  • all detectors are calibrated in our own GAZEX Calibration Laboratory operating in accordance with PN-EN ISO/IEC 17025 (PCA accreditation No AP150).

北京pk彩票app下载

百家欢乐电玩城app下载他將比特幣描述為“對未來的看漲期權”和“世界上最原始的儲備資產”他再次強調,只有嚴格遵守防疫規則,才能避免陷入全國性封鎖

Offered models 北京pk彩票app下载

ModelTypeGas sensor moduleSensorSubstance/propertyStandard alarm thresholds or measuring rangeSupply voltageNet priceC/G
DG/F MS-12/N Semiconductor Methane (CH4)
10/30
%LEL
System powered659.00 złS
DG/F MS-14/N Semiconductor Methane (CH4)
10/30
%LEL
System powered659.00 złS
DG/F MS-15/N Semiconductor Liquefied petroleum gas (LPG)
10/30
%LEL
System powered659.00 złS
DG/F MS-22/NL Semiconductor Carbon monoxide (CO)
20/100
ppm
System powered659.00 złN
DG/F MS-31/N Semiconductor Organic compounds
20/40
%LEL
System powered739.00 złN
DG/F MS-41/N Semiconductor Ammonia (NH3)
500/1500
ppm
System powered699.00 złN
DG/F MS-61/N Semiconductor Hydrofluorocarbons (HFC)
1000/2000
ppm
System powered699.00 złN
DG/F MS-71/N Semiconductor Acetylene (C2H2)
or Hydrogen (H2)
10/30
%LEL
System powered699.00 złN
DG/F MS-72/N Semiconductor Hydrogen (H2)
20/40
%LEL
System powered659.00 złS
DG/F MS-TF Semiconductor Temperature (T)

°C
System powered469.00 złN
DG/F MS-0E.ASH3/N Electrochemical Arsine (AsH3)
0,2/0,4
ppm
System poweredN
DG/F MS-0E.B2H6/N Electrochemical Diborane (B2H6)
0,2/0,4
ppm
System poweredN
DG/F MS-0E.CL2/N Electrochemical Chlorine (Cl2)
1/3
ppm
System poweredN
DG/F MS-0E.CLO2/N Electrochemical Chlorine dioxide (ClO2)
0,1/0,3(TWA/STEL)
ppm
System poweredN
DG/F MS-0E.COCL2/N Electrochemical Phosgene (COCl2)
0,2/0,4
ppm
System poweredN
DG/F MS-0E.ETO/N Electrochemical Ethylene oxide (C2H4O)
2/5
ppm
System poweredN
DG/F MS-0E.HCL/N Electrochemical Hydrogen chloride (HCl)
3,3/6,6(TWA/STEL)
ppm
System poweredN
DG/F MS-0E.HCN/N Electrochemical Hydrogen cyanide (HCN)
3/6
ppm
System poweredN
DG/F MS-0E.NO2/N Electrochemical Nitrogen dioxide (NO2)
1/3
ppm
System poweredN
DG/F MS-0E.NO/N Electrochemical Nitrogen monoxide (NO)
2/–(TWA/STEL)
ppm
System poweredN
DG/F MS-0E.O3/N Electrochemical Ozone (O3)
0,2/0,3
ppm
System poweredN
DG/F MS-0E.PH3/N Electrochemical Hydrogen phosphide (PH3)
0,1/0,2(TWA/STEL)
ppm
System poweredN
DG/F MS-0E.SEH2/N Electrochemical Hydrogen selenide (H2Se)
1/3
ppm
System poweredN
DG/F MS-0E.SIH4/N Electrochemical Silane (SiH4)
5/10
ppm
System poweredN
DG/F MS-0E.SO2/N Electrochemical Sulfur dioxide (SO2)
0.5/1(TWA/STEL)
ppm
System poweredN
DG/F MS-2E/N Electrochemical Carbon monoxide (CO)
20/100
ppm
System powered899.00 złN
DG/F MS-4E/N Electrochemical Ammonia (NH3)
500/800
ppm
System powered999.00 złN
DG/F MS-4E/N1 Electrochemical Ammonia (NH3)
20/40(TWA/STEL)
ppm
System powered999.00 złN
DG/F MS-4E/N2 Electrochemical Ammonia (NH3)
20/40(TWA/STEL)
ppm
System powered1,199.00 złN
DG/F MS-5E/N Electrochemical Hydrogen sulfide (H2S)
5/10(TWA/STEL)
ppm
System powered899.00 złN
DG/F MS-7E/N Electrochemical Hydrogen (H2)
500/800
ppm
System powered999.00 złN
DG/F MS-9E/4 Electrochemical Oxygen (O2)
19/18
%v/v
System powered699.00 złS
DG/F MS-9E/N Electrochemical Oxygen (O2)
19/18
%v/v
System powered849.00 złS
DG/F MS-9E/4-1 Electrochemical Oxygen (O2)
19/18
%v/v
System powered699.00 złS
DG/F MS-1R2/N Infra-red Methane (CH4)
10/30
%LEL
System powered1,599.00 złS
DG/F MS-1R5/N Infra-red Liquefied petroleum gas (LPG)
10/30
%LEL
System powered1,599.00 złS
DG/F MS-3R/N Infra-red Organic compounds
20/40
%LEL
System powered1,739.00 złN
DG/F MS-6R7/N Infra-red Hydrofluorocarbons (HFC)
500/1500
ppm
System powered2,899.00 złN
DG/F MS-6R7/N-SF6 Infra-red Sulfur hexafluoride (SF6)
500/1500
ppm
System powered2,899.00 złN
DG/F MS-8R8/N Infra-red Carbon dioxide (CO2)
0,5/1,5
%v/v
System powered1,099.00 złS
DG/F MS-8R/N Infra-red Carbon dioxide (CO2)
0,5/1,5
%v/v
System powered1,599.00 złN

北京pk赛车7码公式今年8月,耀客傳媒還宣布將與騰競體育聯手,以《英雄聯盟》職業聯賽為創作背景,拍攝以“英雄聯盟”為主題的電視劇今年“雙11”各大電商的“搶先購”活動,普遍比往年來得更早

北京pk彩票app下载

Splash-proof enclosures AP-1
Splash-proof enclosures to protect detectors from adverse weather conditions and mechanical damage
Tubular shields AR-1
Profiled tube guards to protect the detector from direct mechanical damage
DG/w
Adaptation of DG/F, DG/M, DG/P or DG/PV detectors for installation into a ventilation duct
Gas test kits GTS
Test kits for checking the correct functioning of detectors